HYDROPOWER PLANTS

HYDROPOWER MAL PAS, VALLESPIR, MONTENARTRÓ

BASIN Río Santa Magdalena
Location Sal Island, Ponta Preta (República de Cabo Verde)
User Promociones y Proyectos Modolell, S.L.
Date of commissing 1997
Main characteristics
  Montenartró Vallespir Mal Pas
Rated Flow 2.7 cubic meters/d 2.7 cubic meters/d 3 cubic meters/d
Gross Head 165.5 m 187 m 152 m
Power 3639 kw 4217 kw 3797 kw
Annual average output 12.6 GWh 16.7 GWh 17.6 GWh
Generating Groups 1 1 1
Turbines Francis horizontales
Alternators Síncronos trifásicos
3820 kVA 4450 kVA 3995 kVA

HYDROPOWER PLANT LAS AGÜERAS (SPAIN)

BASIN Río Santa Magdalena
Location Término Municipal de Quirós (Asturias, Spain)
User Hidroeléctrica de Quirós
Date of commissing 1994
Main characteristics
Rated Flow 6 cubic meters/d
Gross Head 59,35 m
Power 3.135 kw
Annual average output 12 GWh
Generating Groups 2
Turbines 2 Francis horizontal: 1.045 kW and 2.090 kW
Alternators 2 Synchronous: 1.098 kVA and 2.213 kVA

HYDROPOWER SANTA MARINA(SPAIN)

BASIN Ríos Lindes and Ricabo
Location Término Municipal de Quirós (Asturias, Spain)
User Hidroeléctrica de Quirós
Date of commissing 1994
Main characteristics
Rated Flow 3 cubic meters/d
Gross Head 106 m
Power 2.780 kw
Annual average output 13 GWh
Generating Groups 2
Turbines 2 Francis horizontal: 1.865 kW and 915 kW
Alternators 2 Synchronous: 1.986 kVA and 958 kVA

BIOMASS AND DRY SLUDGES

HOT WATER GENERATION AND DISTRIBUTION BY MEANS OF BIOMASS

LOCATION Molins de Rei, Barcelona, Spain
User Molins Energía, S.L.
Date of commissing 2000
Main characteristics
Net thermal power of the biomass boiler 2.250 kW
Consumption of biomass per year 2.200 ton
Storage silo of biomass 180 m3
Maximum work program 16 h/d
Net thermal power of gas boilers 817 kW
Thermal energy per year 6.776 MWh
Number of users 695
Accumulated hot water 325 m3
Maximum impelled flow 250 m3
Pumps head 2,5 bar
Temperature of the impelled water 90 C

COGENERATION TO DRY SLUDGES IN SEWAGE PLANT

LOCATION Sabadell, Barcelona, Spain
User Sabadell Tractament Térmic
Date of commissing 2001
Main characteristics
Number of cogeneration engines 3
Electriacl power per unit 1.358 kW
Working programme per year 7.000 h
Electrical energy per year 28.518 MWh
Recoveres thermal energy per year 19. 006 MWh
Sludges to be dried per year 21.000 t
Moisture of the sludges to be dried 25 %
Dried sludges 5.833 t
Moisture of the dried sludges < 10 %